How to use: start the signal here, then in LabCast press Start Capture and pick this tab with “Share tab audio” on. Readings should match the table within about ±0.1 dB. A consistent offset on every reading means something in the chain is applying gain.
Sine: 997 Hz is the standard test frequency because it doesn't divide evenly into common sample rates, so every sample phase gets exercised. Web Audio's oscillator is exact to float precision.
Pink noise: equal power per octave, so the Average Spectrum should read flat (within about ±1 dB from 31.5 Hz to 16 kHz once it has averaged for 20+ seconds). Its level is set as RMS per channel. L and R are identical, not independent. The expected loudness is computed from the generated noise buffer itself using the same BS.1770 weighting, so it checks the chain's gain, not the weighting maths (the EBU sine figures cover that).
Capture path: “This tab” capture is taken before the system volume and is the most reliable path. “Entire screen” system audio on Windows can be affected by the per-app level in the Volume Mixer — keep it at 100%.